首頁

 

1. Wastewater Treatment

The BPFM flowmeter can be installed after the final treatment pool of a wastewater treatment system to measure the stream discharge amount.

Normally we use the flowmeter totalizer to estimated the capacity of the wastewater treatment system.


2. Scrubber Circulation Water Measurement

For air pollution control system – Wet Scrubber, we use the circulation water add chemicals to neutralize the polluted elements. To increase the result, the water dosing amount vs. the polluted air amount is very important. We select the flowmeter to measure the dosing water and control the amount.


3. Sea Water Measurement

At cultivation, we construct the piping system to fill the pretreatment sea water into the cultivated pool. And install the flowmeter to calculate the amount, according to make the bill.


4. Cooling Tower System

The flowmeter to calculate the make-up water, and to estimated the vaporized rate. To control and saving the energy.


5. Chemicals Filling

For BPFM high chemical resistance body design, we can apply in the measurement of pure chemicals.

We use the flowmeter to measure the inlet which fill in the tanks. And the totalizer also provide the data of usage.


6. Pure Water ( RO ) System

The BPFM with the Clean PVC fitting can be used to monitor the production of pure water.

And it can be the information about replace the RO films.


7. CIP ( Clean In Place ) Process

In dairy & beverage production steps, the CIP process is very important.

The BPFM in SUS316 body and polished fitting can be apply to monitor the flow rate of sterilized fluid for CIP. The fluid temperature will be 120 deg.C high.


8. Building City Water Supply System

The BPFM can be the indication of the city water supply system. And its optional function can provide a pulse signal to control center as the totalizer data.

The new building emphasized the central management. It can be applied in school, hotel…etc.


9. Swimming Pools

The BPFM use in the swimming pool, to measure the circulation flow rate and indicate the total circulation amount. To keep the cleanness of the swimming pool.


10. Orchard Irrigation

To irrigate the fruit farm, the BPFM flowmeter to match up the irrigate system and control valves. To make sure the irrigation proceeding.

The BPFM don't request the external power supply. It is suitable to apply at such wide field.


11. Electroplating, Surface Treatment Machine

The DNFT apply in Electroplating or Surface Treatment Machine, to measure the chemicals dosing. The actual dosing amount will provide the well quality of products.


12. Wet Processing Machine for PCB

For PCB Wet Processing Machine, we select the DNFT to calculate the chemicals usage.

And the flow rate data transfer to the Human Machine Interface ( HMI ) to manage the suitable circulation amount, and HMI provide the alarm set-point for min. flow rate.


13. Chilling Water System

The DNFT apply in the chilling water system, transfer out the current signal proportional to the flow rate into the control center.

Supplying the flow rate data to calculate the BTU value.


14. Heat Exchanger Unit

The DNFT be installed in the cooling water inlet of the heat exchanger unit to measure the cooling water, meantime the output signal to the control center
to record the change of flow rate, and understanding the efficiency of the heat exchanger. For some applications, the DNFT is suitable to be with the control valve to operation.

 

 

回首頁